4.5.4. Radiation
In normal use, the
e
-Brick generates electromagnetic radiation within allowable limits; refer
to 3.3.6 for relevant standards.
Warning! The
e
-Brick forms part of a GEW UV drying system, providing essential safety
functions. The UV dryer in the system presents some risk of exposure to UV radiation; this
risk is minimised by application specific shielding. Refer to the relevant UV dryer user guides
and system installation manuals for further information.
4.5.5. Gases, Vapours, Dust
The
e
-Brick power supply does not generate any gases, vapours or dust. Refer to 3.3.4 for
recommended operating environment and exposure limits for contaminants.
Note that UV dryers will generate some Ozone (O
3
) that is extracted to atmosphere by the
cooling system. Refer to the relevant UV dryer user guides and system installation manuals
for further information.
4.6. Electrical Data
4.6.1. Block diagram
Master only
RS485 bus
Contactor
Switch mode
Converter
Ignitor
Embedded Control
Press
interface
[P1]
Lamp
output
[P3]
UV
monitor
Shutters
PT100
Chassis
Power
input
[
P5
]
24V DC Supply
Auto
Damper
[P4]
EMC
Filter
Fan
interface
[
P7
]
Optional
Profibus
Interface
[P8]
Comms
out
[P2]
Comms /
HMI in
[P6]
GEW UV
e
-Brick installation and operating manual 22 of 49