22
2 Maintenance
GEZE prescribes frequent maintenance (at least once a year). This is to be carried out by a
specialist company. In the process the function as well as the state of the mechanical equipment
(imbalance or signs of wear, damage to fastening parts) and the power line are to be checked.
The system may not be used during repair and setting work.
3 Technical data (one drive)
The chain drive E740 Syncro is equipped with a novel system for coordinated synchronisation of
the chain movement. The casement is moved in an even form without speed variations of the
two drives. If (for mechanical or electrical reasons) one of the two drives does not function and
stops, the other drive also stops and thus guarantees that the window remains undamaged. The
electronic speed control is fully automatic and does not require an external control element.
Mechanical data E740 Syncro (per drive)
Thrust [N] 250
Pulling force [N] 300
Travel speed [mm/s] 7
End position deactivation extended Integrated displacement sensor
End position deactivation retracted Power consumption
Overload deactivation Via current consumption
Weight [kg] Approx. 1.7
Stroke length [mm] selectable via rotary switch 100/200/300/400
Subject to technical modications!
Electrical data E740/24 V Syncro Electrical data E740/230 V Syncro
The end position cut-o of each drive operates automatically when the window closes. Pressing of the
seals with a pulling force of more than 300 N.
Voltage [V DC] 24 ±25% SELV
Max. residual ripple Uss [%] 20
Load factor [%] 30
Power consumption [W] 22
Current consumption [A] 0.9
Ambient temperature [°C] -5 / +70
Enclosure rating [IP] / pro-
tection type
42/III
Range of application Dry rooms
Voltage [V AC] 230 ±10%
Frequency [Hz] 50
Load factor [%] 30
Operating time [min.] 4
Power consumption [W] 30
Current consumption [A] 0.13
Ambient temperature [°C] -5 / +70
Enclosure rating [IP] / protection type 42 / II
Range of application Dry rooms