EasyManua.ls Logo

GEZE E740 Syncro - Connection E740;230 V Syncro

GEZE E740 Syncro
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
1 selector
switch
Connection
Power supply cable 230 V AC
CLOSED
N
OPEN
Switch a max. of 10 drives in paral-
lel (to 1 selector switch)
E740/230 V AC Syn.
M1
COM
M2
RX
TX
BN"CLOSED"
BU"N"
BK"OPEN"
RD
WH
E740/230 V AC Syn.
M1
COM
M2
RX
TX
BN"CLOSED"
BU"N"
BK"OPEN"
RD
WH
E740/230 V AC Syn.
M1
COM
M2
RX
TX
BN
BU
BK
RD
WH
E740/230 V AC Syn.
M1
COM
M2
RX
TX
BN
BU
BK
RD
WH
Junction box
L1 N PE
7.2 Connection E740 / 230 V Syncro
Cable laying (further drives analogue)
1 selector
switch
Power supply cable
3x1.5 mm² with GN/YE
Cables: 4x1.5 mm² with GN/YE
or 3x1.5 mm² without GN/YE
Junction box
Connecting cable 5x0.75 mm², approx. 5 m
Controlling of more than
1 operating point is possible with
self-holding module (Mat. No. 29343)
and keys
E740/230 V AC
Syncro
E740/230 V AC
Syncro
E740/230 V AC
Syncro
E740/230 V AC
Syncro
Junction box
Conductor colours:
BN = Brown
BU = Blue
BK = Black
GN/YE = Green/yellow
RD = Red
WH = White
Junction box
The connecting cables must not be extended!