ECturn & ECturn Inside
15
Cleaning and maintenance
6 Cleaning and maintenance
6.1 Cleaning
CAUTION!
Danger of injury due to impact and crushing!
X
Set the mode of operation to OFF.
X
Secure door leaves against accidental movement before carrying out cleaning work.
What is to be cleaned? How is it to be cleaned?
Safety indicator SIS/ SIO
X
Wipe with damp cloth
Stainless surfaces
X
Wipe with soft cloth
Coated surfaces
X
Wipe with water and soap
Anodised surfaces
X
Wipe with non-alkaline potassium soap (pH value 5.5…7)
Display programme switch, keypad programme
switch, mechanical programme switch
X
Wipe with soft cloth. Do not use a cleaning agent
6.2 Maintenance
The operator must ensure that the system is working perfectly. To guarantee perfect operation, the door system
must be serviced regularly by a service technician.
Maintenance must be carried out at least once a year or according to the maintenance display on the display
programme switch.
Installation, maintenance and repair work must be performed by experts authorised by GEZE.
GEZE oers maintenance contracts with the following services:
à Inspection of fastening elements for rm t
à Performance of miscellaneous adjustment work
à Performance of operational checks
à Checking all the safety and control equipment of the door system
à Lubrication of all the moveable parts
6.3 Inspection by trained professionals
In compliance with the “Guidelines for windows, doors and gates” (ASR A1.7 and GUV 16.10) Section 6, power-op-
erated doors must be inspected for safety by an expert before initial commissioning and at least once a year.
GEZE oers the following services:
Inspection and operational checks of all safety and control equipment in compliance with the requirements in
the log book for power-operated windows, doors and gates; Sliding doors and sliding gates ZH 1/580.2 edition.
210623_GEZE_ID 196257-00_BHB-ECturn_EN.indd 15 7/18/2021 14:00:32