Technical data
8 Technical data
ECturn Ecturn Inside
Mains voltage 110 to 230 V ±10 % 110 to 230 V ±10 %
Frequency 50 to 60 Hz 50 to 60 Hz
Protection rating I II
Capacity rating 75 W 92 W
Mains connection Protective contact plug (plug type F,
CEE7/4) or xed connection (installation
cable or drip loop)
Fixed connection (installation
cable or drip loop)
Primary fuse 4 AT, 5×20 mm -
Secondary fuse 0.75 AT, 5×20 mm 0.75 AT, 5×20 mm
Secondary voltage power supply 24V DC 24V DC
Control voltage for external compo-
nents
24 V DC ±10% 24 V DC ±10%
Max. output current control voltage 24 V
600 mA 600 mA
Rechargeable battery NiMH 19.2 V, 650 mAh NiMH 19.2 V, 650 mAh
Temperature range 15...+50 °C 15...+50 °C
IP rating IP20 IP20
210623_GEZE_ID 196257-00_BHB-ECturn_EN.indd 17 7/18/2021 14:00:33