- 101 - BIOS Setup
Parameter
Description
System Agent VR Settings/
Core/IA VR Settings/
GT-UnSliced VR Settings/
GT-Sliced VR Settings
(continued)
PS4 Enable
Enable/Disable PS4.
Options available: Enabled/Disabled. Default setting is
Enabled.
IMON Slope
Sets a value for IMON Slope which is defined in 1/100
increments. The range is 0-200. Default setting is 0.
IMON Offset
Sets a value for IMON Offset which is defined in 1/1000
increments. The range is 0-63999. Default setting is 0.
IMON Prex
Sets the offset value as positive or negative.
VR Current Limit
Sets a value for Voltage Regulator Current Limit. The value
represents the maximum instantaneous current allowed at
any given time.The value is represented in 1/4A (Ampere)
increments. A value of 400 equals 100A. Default setting is 0.
VR Voltage Limit
Sets a value for VR Voltage Limit which is dened in mV.
The range is 0-7999mV, Default setting is 0.
TDC Enable
Enable/Disable TDC.
Options available: Enabled/Disabled. Default setting is
Enabled.
TDC Current Limit
Sets a value for TDC current Limit which is dened in 1/8A
increments. The range is 0-32767. Default setting is 0.
TDC Time Window
Options available: 1ms, 2ms, 3ms, 4ms, 5ms, 6ms, 7ms,
8ms, 9ms, 10ms. Default setting is 1ms.
TDC Lock
Enable/Disable TDC Lock.
Options available: Enabled/Disabled. Default setting is
Disabled.
VR Mailbox Command options
VR mailbox commands to send, 1:MPS VR cmd, 2:PS4 Exit VR
cmd, 4:MPS VR Decay cmd. It can select multiple commands by
entering sum of values of each command.