Intrinsically Safe WindObserver Anemometer Page 46 Issue 10
Doc. No. 1360-PS-0001 May 2015
Mx to Mxx - Message Format
Output format
Configuration code
ASCII UV Continuous
M1
ASCII Polar Continuous
M2
ASCII UV Polled (tri
-
state)
M3
ASCII Polar Polled (tri
-
state)
M4
NMEA Continuo
us
M5
Binary Tunnel Continuous
M6
Binary UV Continuous
M7
Binary Polar Continuous
M8
ASCII Tunnel Continuous
M12
ASCII Tunnel Polled (tri
-
state)
M13
ASCII Polar Polled Averaged
M14
ASCII Polar Continuous Averaged
M15
Nx - Node Address (A default)
Item Options Command
Node Address
A -(A to Z)
N<A>
Ox – ASCII Output Format (Output String Padding)
Setting
Configuration code
Comma Separated Variable (CSV)
O1
Fixed Field
O2
Example data strings:-
POLAR
NMEA
CSV
data changing to error status cod
e
condition.
CSV
data changing to error status code
condition.
A,235,000.77,M,00,
0A
$IIMWV,191,R,000.55,M,A*19
A,,,M,04,
24
$IIMWV,,R,,M,V*29
Fixed Field
data changing to error status
code condition.
Fixed Field
data changing to error status
code condition.
A,266,000.73,M,00,
08
$IIMWV,191,R,000.55,M,A*19
A,999,999.99,M,04,
0A
$IIMWV,999,R,999.99,M,V*07
Px - Output Rate
Outputs per second
1
2
4
Configuration code
P1 P3 P2

Table of Contents