9. Specifications
Operating Range Utility Frequency
Model
The max DC input voltage
MPPT operation range
The max dc input current
Number of MPPT/strings per MPPT
Rated output power
The max. transient power
Rated grid voltage
The grid voltage range
Operation phase
Rated grid output current
Output power factor
Grid current THD
The dc injection current
Rated grid frequency
Max. Efficiency
Protection
Size(mm)
Weight
Topology
Internal consumption
Running temperature
Ingress protection
Interface
Design lifetime
Utility Monitoring
Operation Surroundings Humidity
EMC
1000Vdc
15+15Adc
2/1
400Vac
313470Vac(adjustable)
Three phase
>0.99
<4%(Total THD)
<20mA
50/60Hz
>97.5%
430W*600H*220Dmm
27kg
Transformerless
-2560
IP65
Rs485 WIFI GPRS(Optional)
>20years
47-52 or 57-62Hz(adjustable)
095%
EN61000-6-1:2007
EN61000-6-3:2007
Solis-6K
200800Vdc
6kW
6.6kW
8.7Aac
<6W(Night)
Islanding protection V F in accordance with UL 1741,
AC AC
G59/3, AS4777,VDE 0126-1-1, VDE 4105, CEI 0-21,CQC
.31..30.
9. Specifications
Operating Range Utility Frequency
Model
The max DC input voltage
MPPT operation range
The max dc input current
Number of MPPT/strings per MPPT
Rated output power
The max. transient power
Rated grid voltage
The grid voltage range
Operation phase
Rated grid output current
Output power factor
Grid current THD
The dc injection current
Rated grid frequency
Max. Efficiency
Protection
Size(mm)
Weight
Topology
Internal consumption
Running temperature
Ingress protection
Interface
Design lifetime
Utility Monitoring
Operation Surroundings Humidity
EMC
Solis-10K
1000Vdc
200800Vdc
18+18Adc
2/2
400Vac
313470Vac(adjustable)
Three phase
>0.99
<4%(Total THD)
<20mA
50/60Hz
>97.5%
430W*600H*220Dmm
Transformerless
-2560
IP65
RS485 WIFI GPRS(Optional)
>20years
47-52 or 57-62Hz(adjustable)
095%
EN61000-6-1:2007
EN61000-6-3:2007
<6W(Night)
Islanding protection V F in accordance with UL 1741,
AC AC
G59/3, AS4777,VDE 0126-1-1, VDE 4105, CEI 0-21,CQC
Solis-15K
15kW
15kW
21.7Aac
30kg
18+18Adc
2/2
10kW
11kW
14.5Aac
Solis-20K-HV
20kW
20kW
24Aac
480Vac
427523Vac(adjustable)