Supplied By www.heating spares.co Tel. 0161 620 6677
3
221504A
Introduction
Please read these instructions and follow them carefully for the
safe and economical use of your boiler.
The Economy Plus “F” Range are boilers designed to provide
central heating and indirect domestic hot water from a fully
pumped system with a fully indirect cylinder.
Important Notice
This boiler is for use only on natural gas G20 gas.
Gas Safety (Installation and Use) Regulations.
In your interest and that of gas safety it is the Law that ALL gas
appliances are installed by a competent person in accordance
with the current issue of the above regulations.
Gas Leak or Fault
If a gas leak or fault exists or is suspected, the BOILER MUST
BE TURNED OFF, including the electrical supply and MUST
NOT BE USED UNTIL THE FAULT HAS BEEN PUT RIGHT.
Advice/help should be obtained from your installation/servicing
company or the local gas undertaking.
Maintenance/Servicing
To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
depend upon the particular installation conditions and usage,
but in general once a year should be enough.
If this appliance is installed in a rented property there is a duty
of care imposed on the owner of the property by the current
issue of the Gas Safety (Installation and Use) Regulations,
Section 35.
It is the Law that any servicing must be carried out by a
competent person.
To obtain service, please call your installer or Heatcall (Glow-
worm’s own service organisation) using the telephone number
given on the case tray.
Boiler Clearances
If fixtures are positioned close to the boiler space must be left
as shown in diagram 1. Enough space must also be left in front
of the boiler to allow for servicing.
Boilers Installed in a Compartment or
Cupboard
If the boiler is installed in a cupboard or compartment do not
obstruct any ventilation openings.
Do not use the cupboard or compartment for storage.
Regularly make sure that the air vent openings are clear of
obstructions.
Cleaning
WARNING. This appliance contains metal parts (components)
and care should be taken when handling and cleaning, with
particular regard to edges.
Clean the casing occasionally by wiping it over with a damp
soapy cloth or dry polishing duster.
Do not use an abrasive cleaner.
Boiler Electrical Supply
WARNING. The boiler must be earthed.
The boiler must only be connected to a 240V~50Hz supply,
protected by a 3A fuse.
All wiring must be in accordance with the current issue of
BS7671.
The colours of three core flexible cable are:
Brown - live, blue - neutral, green and yellow - earth.
As the markings on your plug may not correspond with these
colours, continue as follows,
The wire coloured blue must be connected to the terminal
marked “N” or “Black”.
The wire coloured brown must be connected to the terminal
marked “L” or “Red”.
The wire coloured green and yellow must be connected to the
plug terminal marked “E” or “Green” or the earth symbol "
" .
Electrical Supply Failure
Failure of the electrical supply will cause the burner to go out.
Should this happen, operation of the appliance will normally
resume after the electrical supply is restored.
If the burner does not relight after an electrical supply failure the
overheat device may need resetting, refer to diagram 2, remove
the controls tray and press the reset button.
If the cutoff occurs again, turn the appliance off and contact your
installation/servicing company.
Instructions for Use
PERMANENT
SURFACE
DD
B
A
3540
150
EE
3540
CLEARANCES
Diagram 1