4
221504A
Data/Serial Number Label
The GC number of the appliance can be found on the Data label,
positioned at the top right of the inner cover.
The model name and serial number are located on the control
box cover, visible when the controls tray is removed.
To Turn the Boiler On
Sealed Water Systems.
CAUTION. A sealed water system must be filled and pressurised
by a competent person.
Only light the boiler when you are sure that the system and
boiler have been filled and pressurised.
The pressure gauge should show at least 0.7bar, anything less
than this figure could indicate a leak and you MUST contact your
installation/servicing company.
If there is any doubt about the boiler being full of water consult
your installation/servicing company.
All Systems
Turn the electrical supply on to the boiler and check that any
remote controls are set to your requirements (refer to
manufacturer’s instructions for these items).
Remove the controls tray by withdrawing it forwards.
Turn the boiler thermostat knob clockwise to any position
between “MIN” and “MAX”, see diagram 2. The maximum
setting is about 82
o
C (180
o
F).
The boiler lighting operation is now automatic as follows:
The fan operates, followed by an ignition spark until the pilot is
lit. When the pilot is alight the ignition switches off and the main
burner lights. The flames can be seen through the viewing
window.
The main burner will remain alight until switched off by the boiler
thermostat or other remote control.
If the boiler thermostat is turned Off, by hand, wait at least 30
seconds before turning on again.
When the boiler goes off, both the pilot and main burner go out.
The automatic lighting sequence will operate again when heat
is required.
Refit the controls tray.
To Turn the Boiler Off
For short periods, turn thermostat control knob anti-clockwise
until “O” is against the setting point. To relight the main burner,
turn the thermostat knob clockwise to any setting between ”MIN”
and “MAX”.
For longer periods, turn the thermostat control knob anti-
clockwise until “O” is against the setting point.
Switch off the electrical supply to the boiler.
To relight follow the sequence given above.
Protection Against Freezing
If the boiler is to be out of use for any long period of time during
severe weather conditions we recommend that the whole of the
system, including the boiler, be drained off to avoid the risk of
freezing up. Make sure that, if fitted, the immersion heater in the
cylinder is switched off.
If you have a sealed water system contact your installation/
servicing company as draining, refilling and pressurising must
be carried out by a competent person.
Diagram 2
BOILER CONTROLS
3560
VIEWING
WINDOW
CONTROLS TRAY
BOILER THERMOSTAT CONTROL KNOB
OVERHEAT
CUT-OFF
RESET
BUTTON
SERIAL No.
SETTING
POINT
Instructions for Use