5
221504A
102
63
360
600
45
86
60
42
300
WATER CONNECTIONS FLUE
TERMINAL
DETAIL
GAS CONNECTIONS
=
=
122
*
55
from boiler top.
58mm from inner case top.
*
122
1 General
Diagram 1.1GENERAL ARRANGEMENT
6472
MODEL
LIFTING
WEIGHT
Rc
1
/
2
(
1
/
2
in. BSPT)
GAS
CONNECTION
WATER
CONNECTION
28mm copper,
flow at right, return at left
65W, internal fuse F1A.
ELECTRICITY
RATING
WATER
CONTENT
TOTAL
WEIGHT
240V~50Hz Fused 3A
DATA LABEL
On the inner case front
TABLE 1.
ECONOMY PLUS
DATA
ELECTRICITY
SUPPLY
0.8Litre
(1.4pt)
33.0Kg
(72.8lb)
26.5Kg
(58.4lb)
60F
1.1 Important Notice
This boiler is for use only on G20 gas.
The boiler is delivered in one pack.
Wherever possible, all materials, appliances and components
to be used shall comply with the requirements of applicable
British Standards.
Where no British Standard exists, materials and equipment
should be fit for their purpose and of suitable quality and
workmanship.
This boiler must have fully pumped circuits, but is suitable for
use with open vented or sealed systems.
This boiler is not suitable for outdoor locations.
1.2 Sheet Metal Parts
WARNING. When installing or servicing the boiler care should
be taken when handling sheet metal parts to avoid any possibility
of personal injury.
1.3 Statutory Requirements
The installation of the boiler MUST be carried out by a competent
person in accordance with the relevant requirements of the
current issue of:
Manufacturer’s instructions, supplied.
The Gas Safety (Installation and Use) Regulations, The Building
Regulations, The Building Standards (Scotland) Regulations
(applicable in Scotland), local Water Company Bye-laws, The
Health and Safety at Work Act, Control of Substances Harmful
to Health, The Electricity at Work Regulations and any applicable
local regulations.