Adapting the unit to the heating installation 10
0020300877_01 Energy
7
Installation and maintenance instructions 35
10 Adapting the unit to the heating
installation
You can reset/change the system parameters (section "Us-
ing diagnostics codes").
Overview of diagnostics codes ( Page 45)
10.1 Burner anti-cycling time
To prevent frequent switching on and off of the burner and
thus prevent energy losses, an electronic restart lockout
is activated for a specific period each time the burner is
switched off. The burner anti-cycling time is only active for
the heating mode. Domestic hot water mode during a burner
anti-cycling time does not affect the time function element.
10.1.1 Setting the maximum burner anti-cycling
time
Set diagnostics code . ( Page 29)
Overview of diagnostics codes ( Page 45)
10.1.2 Resetting the remaining burner anti-cycling
time
Press and hold the reset button for more than
three seconds.
is shown in the display.
11 Handing over to the end user
At the time of commissioning complete all relevant sec-
tions of the Benchmark commissioning checklist, located
at the rear of this document.
For IE: Complete a “Declaration of Conformity” to indicate
compliance to I.S. 813. An example of this is given in the
current edition of I.S. 813.
When you have finished the installation, affix the en-
closed sticker (which requests that the user reads the
instructions) to the front of the product in the end user's
language.
Draw attention, to the current issue of the Gas Safety
(Installation and Use) Regulations, Section 35, which
imposes a duty of care on all persons who let out any
property containing a gas appliance in the UK.
Explain to the end user how the safety devices work and
where they are located.
Inform the end user how to handle the product.
In particular, draw attention to the safety warnings that
the end user must follow.
Inform the end user that they must have the product
maintained in accordance with the specified intervals.
Pass all of the instructions and documentation for the
product to the end user for safe-keeping.
Inform the end user about measures taken to ensure
the supply of combustion air and flue gas guiding, and
instruct the operator that he must not make any changes.
Inform the end user that they must not store or use explo-
sive or highly flammable substances (such as petrol, pa-
per or paint) in the installation room of the product.
Complete and sign off the Benchmark commissioning
check list.
Complete and sign off the guarantee documentation.