Appendix
0020300877_01 Energy
7
Installation and maintenance instructions 47
Setting level Values
Unit Increment, select, explanation
Default set-
ting
Own setting
Min. Max.
d.68 Number of unsuccessful
ignitions at 1st attempt
Current value Not
adjustable
d.69 Number of unsuccessful
ignitions at 2nd attempt
Current value Not
adjustable
d.71 Maximum target heating
flow temperature
45 80 1 75 Adjustable
d.75 Maximum cylinder post-
heating time
20 90 min 1 45 Adjustable
d.77 Max. cylinder post-heat-
ing
kW 1
Section "Technical data"
Adjustable
d.78 DHW max. flow temperat-
ure
50 80 1 Adjustable
d.80 Running time in heating
mode
Current value h Not
adjustable
d.81 Running time in DHW
mode
Current value h Not
adjustable
d.82 Number of burner igni-
tions in heating mode
Current value Number of ignitions = Display value x
100
Not
adjustable
d.83 Number of burner igni-
tions in DHW mode
Current value Number of ignitions = Display value x
100
Not
adjustable
d.84 Maintenance in 0 3000 h Number of hours = Display value x 10 300 Not
adjustable
d.85 Increase in the min. out-
put (heating and DHW mode)
kW 1
Section "Technical data"
Adjustable
d.90 Status of the eBUS room
thermostat
Current value off = Not connected
on = Connected
Not
adjustable
d.93 Setting the product code 0 99 1 Adjustable
d.94 Delete fault list 0 1 off = No
on = Yes
Adjustable
d.95 Software versions 1 = Main PCB
2 = Interface PCB
Adjustable
d.96 Reset to factory settings 0 = No
1 = Yes
Adjustable
d.128 Heating minimum target
value
10 75 1 10 Adjustable
d.129 Domestic hot water min-
imum target value
35
(combi
boiler)
45
(sys-
tem
boiler)
60 1 35 Adjustable
D Status codes Overview
Status code Meaning
Displays in heating mode
S. 0 Heating mode: No requirement
S.01 Heating mode: Fan prerun
S.02 Heating mode: Pump prerun
S.03 Heating mode: Burner ignition
S.04 Heating mode: Burner on
S.05 Heating mode: Pump/fan overrun
S.06 Heating mode: Fan overrun
S.07 Heating mode: Pump overrun
S.08 Heating mode: Temporary shutdown after heating procedure