SECTION VIIC SERVICE PROGRAMMING SYSTEM
2005 Tech 2 User’s Guide VII - 53
8. At the Calibration Selection screen (Figure VIIC-7):
Select the appropriate calibration(s).
Make sure all folder tabs have a green check mark.
Select Next.
9. At the Summary screen (Figure VIIC-9):
Verify current calibration(s) with selected calibration(s).
Select Next.
If calibrations are the same, the NAODRUI Control box will appear (Figure VIIC-10). Select OK.
On model year 1996 and newer controllers, a Crankshaft Position notice may appear under
“Controller Specific Instructions” on the Program Controller screen. Select OK.
The Transfer Data screen appears (Figure VIIC-11) as reprogramming begins, finishing when the
percentage bar reaches 100 per cent. This may take up to 30 minutes.
IMPORTANT
Some vehicles will require that Idle Learn, TP Learn, Theft Deterrent Relearn, or Crankshaft Variation
Learn procedures be performed after programming. Consult the appropriate service information for
these procedures.
Pass-Thru Programming continued on next page...