9. Commissioning/charging
5. Stop charging
The charging process is completed when the LEDs
light up green.
If you want to stop charging prematurely, use the
„cable release“ function of your vehicle or the large
round button of the go-e Charger app (tab „Char-
ging“).
The cable remains locked in the type 2 socket in the
standard setting after the charging process has en-
ded (adjustable via the app) until it is removed from
the vehicle (theft protection).
If the power supply is interrupted, the charging ca-
ble remains locked in the charging box for reasons
of theft protection. To unlock it, it is necessary to re-
energise the charging station. The cable can also be
unlocked automatically after a power failure, provi-
ded the function has been activated in advance via
the „Cable unlock“ setting in the app. However, it is
then no longer theft-protected in the event of a pow-
er failure.
4. Charging
After the car has enabled charging, the LEDs rotate
clockwise around the type 2 socket during the char-
ging process.
The number of „tails“ corresponds to the number of
connected phases or the number of phases set in the
app:
• 1 rotating tail = 1-phase charging (230 V)
• 3 rotating tails = 3-phase charging (400 V)
The speed of rotation and length of the tails indicate
the amount of charging current.
The go-e Charger displays the charging status via dif-
ferent colours and positions of the LEDs. In addition,
it executes a whole series of safety queries to check
the used power source for possible errors. For this
reason, the go-e Charger may display an error and
refuse to charge, especially with unknown power
sources.
The device visualises the cause of the error by certain
colours and positions of the LEDs. You can also nd
the error message within the „Status“ information of
the app. (The following colour codes correspond to
the factory setting).
Ground check deactivatedGround check deactivated
4 LEDs light up red (3, 6, 9 and 12 o‘clock).
The go-e Charger has the safety function „ground
check“, which prevents the charging process in TT/
TN power grids (common in most European count-
ries) in case of insucient grounding of the pow-
er connection. This function is enabled by default
and can be disabled via the go-e Charger app.
However, the „Ground check“ should only be disa-
bled if you are sure that the electricity grid has no
grounding (IT grid, e.g. in many regions of Norway),
so that charging can also be carried out here. If you
are not sure, you must leave the setting in the app at
„Enabled“!
WaitingWaiting
The LEDs ash blue in the number of preset charging
power.
The go-e Charger waits to charge based on a preset
sheduler or to obtain cheap electricity when charging
with a exible electricity tari.
10. LED status display/troubleshootingoting