Number of flashes that will activate over-temperature protection:
Power Output Level
Number of Flashes
1/1
30
1/2 + 0.7
40
1/2 + 0.3
50
1/2
60
1/4 (+0.3, +0.7)
100
1/8 (+0.3, +0.7)
200
1/16 (+0.3, +0.7)
300
1/32 (+0.3, +0.7)
500
1/64 (+0.3, +0.7)
1000
1/128 (+0.3, +0.7)
Number of flashes that will activate over-temperature protection in high-
speed mode:
Power Output Level
Number of Flashes
1/1
15
1/2 (+0.3, +0.7)
20
1/4 (+0.3, +0.7)
30
1/8 (+0.3, +0.7)
1/16 (+0.3, +0.7)
40
1/32 (+0.3, +0.7)
1/64 (+0.3, +0.7)
50
1/128 (+0.3, +0.7)
Protection Function
Other Protections
The system provides real-time protection to secure the device and your safety. The
following lists prompts for your reference:
Prompts on
LCD Panel
Meaning
E0
A failure occurs on the temperature sensor.
Please send this kit to a maintenance center.
E1
A failure occurs on the recycling system so that the flash cannot fire.
Please restart the flash unit. If the problem still exists, please send
this product to a maintenance centre.
E2
The system gets excessive heat. Please allow a rest time of 10
minutes.
E3
The voltage on two outlets of the flash tube is too high. Please send
this product to a maintenance centre.