63
User Manual V1.4-2022-08-30 10 Technical Parameters
Self-consumption at Night (W)
*2
<10
Ingress Protection Rating IP65
DC Connector MC4 (4~6 mm
2
)
AC Connector Quick Plug
Environmental Category 4K4H
Pollution Degree III
Overvoltage Category DC II / AC III
Protective Class I
Storage Temperature (℃) -40~+85
The Decisive Voltage Class (DVC)
Battery: C
PV: C
AC: C
Com: A
Mounting Method Wall Mounted
Active Anti-islanding Method AFDPF + AQDPF
*3
Type of Electrical Supply System Single phase TN/TT system
Country of Manufacture China
Certication
Grid Standards C10/11
Safety Regulation IEC/EN 62109-1&2
EMC
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4,
EN 61000-4-16, EN 61000-4-18, EN 61000-4-29
*1: CAN communication is congured by default. If 485 communication is used, please replace
the corresponding communication line.
*2: No Back-up Output.
*3: AFDPF: Active Frequency Drift with Positive Feedback, AQDPF: Active Q Drift with Positive
Feedback.

Other manuals for Goodwe EH Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe EH Plus Series and is the answer not in the manual?

Goodwe EH Plus Series Specifications

General IconGeneral
BrandGoodwe
ModelEH Plus Series
CategoryInverter
LanguageEnglish

Related product manuals