Please set it according to the battery
technical parameters.
Constant Charging
Voltage
The battery charging mode is set to constant
voltage charging by default; this value is the
upper limit of charging voltage in this mode.
Please set it according to the battery
technical parameters.
Minimum discharge
voltage
Please set it according to the battery technical
parameters. To protect the battery performance
and life, this parameter should not be set too
low.
The maximum current during charging, used to
limit the charging current. Please set it
according to the battery technical parameters.
Please set it according to the battery technical
parameters. The greater the discharge current is,
the shorter the working time of the battery is.
Maximum floating
charge current
The maximum charging current in the floating
charge state. Please set it according to the
battery technical parameters.
When the battery is nearly fully charged, it will
enter the floating charge state. Please refer to
the technical parameters of the corresponding
battery model for specific definitions.
Battery Internal
Resistance
The internal resistance of the battery. Please set
it according to the battery technical parameters.
Time to switch to
float charging mode
When the battery charging status changes from
constant charging to float charging, and the
duration reaches the set value, the battery
charging mode will switch to float charging
mode. The default duration is 180s.
Charge temperature
compensation
By default, when the temperature is higher than
25℃, the upper limit of charging voltage will
decrease by 3mV for every 1℃ increase. The
actual settings should be based on the technical