Note:
When sunlight is insufficient, the PV Inverter may continuously start up and shut down automati-
cally due to insufficient power generation by the PV panel.
1. Turn off DC switch of the inverter.
2. Wait till the inverter's LCD light is off.
3. Turn on DC switch and make sure it is connected.
4. If the problem still exists, contact local service office for help.
1. Turn off DC switch, take off DC connector, measure the voltage of PV array.
2. Plug in DC connector, and turn on DC switch.
3. If PV array voltage is lower than 250V , please check configuration of inverter
module.
4. If voltage is higher than 250V , please contact local office.
Type of fault Troubleshooting
Relay-Check Failure
DCI Injection High
EEPROM R/W Failure
SCI Failure
SPI Failure
DC BUS High
BUS Unbalance
GFCI Failure
Ifan Fault
Efan Fault
Afan Fault
No display
Wi-Fi module fail to
connect to network
Inverter
Failure
Others
1. If the Wi-Fi module fail to connect to network after choosing the right router
hotspot and entering the right passwords,it's possible that there are special
characters not supported by module in the hotspot passwords. Please modify
the password to consist of only Arabic numerals or uppercase / lowercase
letters.
2. If the problem still exists, contact local service office for help.
7 Technical Parameters & Block Diagram
7.1 Technical Parameters
Technical Data
DC Input Data
Max. PV Power (W)
Max. DC Input Voltage (V)
MPPT Range (V)
Starting Voltage (V)
Min. Feed-in Voltage(V)
Nominal DC Input Voltage (V)
Max. Input Current (A)
Max. Short Current (A)
No. of MPP Trackers
No. of Input Strings per Tracker
AC Output Data
Nominal Output Power (W)
Max. Output Power (W)
Max. Output Apparent Power (VA)
Nominal Output Voltage (V)
Nominal Ouput Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nominal Output)
Efficiency
Max. Efficiency
European Efficiency
Protection
PV String Current Monitoring
Anti-islanding Protection
Input Reverse Polarity Protection
Insulation monitoring
DC fuse
Anti-PID Function for Module
DC SPD Protectioin
AC SPD Protectioin
Residual Current Monitoring Unit
AC Over Current Protection
AC Short Protection
AC Over Voltage Protection
General Data
Ambient Temperature Range (℃)
Relative Humidity
Operating Altitude (m)
Cooling
Display
Communication
Weight (kg)
Dimension (Width*Height*Depth mm)
Protection Degree
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC Regulation
GW30KLV-MT
54000
800
200~650
200
210
370
30/30/20/20
38/38/25/25
4
3/3/2/2
30000
28800
30000
33000
33000
150~300
50/60
80
98.7%
98.3%
LCD or WiFi+APP
RS485 or WiFi
59
586*788*264
GW35KLV-MT
63000
800
200~650
200
210
370
30/30/30/30
38/38/38/38
4
3/3/3/3
36000
34500
36000
39900
39900
150~300
50/60
96
98.8%
98.5%
LCD or WiFi+APP
64
586*788*264
GW50KLV-MT
90000
800
200~650
200
210
370
44/44/44/44
55/55/55/55
4
4/4/4/4
50000
47300
50000
55000
55000
150~300
50/60
133
98.7%
98.3%
LED, WiFi+APP
RS485&WiFi, PLC(Optional)
70
586*788*267
~1 (Adjustable from 0.8 leading to 0.8 lagging)
<3%
Integrated
Integrated
Integrated
Integrated
Integrated
Optional
Integrated(Type II)
Integrated(Type II)
Integrated
Integrated
Integrated
Integrated
-30~60
0~100%
≤4000
Fan Cooling
RS485 or WiFi
IP65
<1
Transformerless
Visit homepage to achieve information.
208VAC
220VAC
240VAC