Operation
26 334530E
11. With prime valve horizontal. Trigger gun
into flushing pail to purge fluid from hose.
12. Engage trigger lock.
13. Turn pressure control knob to OFF and
turn ON/OFF switch to OFF position.
Disconnect power to sprayer.
14. Remove filter from gun and sprayer if
installed. Clean and inspect. Install filter.
See separate gun manual.
15. If flushing with water, flush again with
mineral spirits or Pump Armor to leave a
protective coating to prevent freezing or
corrosion.
16. Wipe sprayer, hose and gun with a rag
soaked in water or mineral spirits.