Operation
3A7031A 19
Alarm ID Alarm Type Alarm Icon Cause Solution
A17 (INPUT 1)
A18 (INPUT 2)
Sensor
Fault
Sensor input is out
of range for given
type
Inspect the sensor and wiring.
Confirm that the programming is correct.
A14 Machine
Count
Timeout
The machine use is
low.
Confirm that the controller settings are correct
for machine usage.
The cabling to
machine count is
broken.
A23 Solenoid
Failure
No Symbol The solenoid valve
used to control the
lubrication flow has
failed.
Replace the solenoid valve used to control
lubrication flow.
A12 Generic
Input
No Symbol The user defined
input is active and
requires attention.
Resolve the system issue. Clear the alarm
when the system issue is resolved.