Repair
8 309577T
Repair
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1. Relieve pressure in gun and perform gun shutdown
procedure. See gun manual.
2. Close gun fluid manifold valves A and B.
3. Shut off feed pumps and agitator, if used.
4. Turn PRESSURE RELIEF/SPRAY valves (ASA,
SB) to PRESSURE RELIEF. Route fluid to waste
containers or supply tanks. Ensure that gauges drop
to 0.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief Pro-
cedure when you stop spraying and before cleaning,
checking, or servicing the equipment.
TI2421A
TI2481a
SA
SB