For the application of line striping materials.
For professional use only.
For outdoor use only.
Not for use in explosive atmospheres or hazardous locations.
Maximum Operating Pressure: 3300 psi (22.8 MPa, 228 bar)
Important Safety Instructions
Read all warnings and instructions in this manual and in related manuals.
Be familiar with the controls and the proper usage of the equipment.
Save these instructions.
LineLazer 130HS
Model: Standard
1 Manual Gun
Standard
2 Manual Guns
17H447
17H448
Related Manuals:
3A3391 Parts
311254 Gun
311845 Pump
Operation
LineLazer
130HS Airless Line Stripers 3A3392B
EN
Use only genuine Graco replacement parts.
The use of non-Graco replacement parts may void warranty.
ti28037a

Other manuals for Graco LineLazer 130HS

Questions and Answers

  • D
    Daniel TaylorSep 10, 2025
    What to do if Graco LineLazer 130HS Construction Equipment fluid is spitting from gun?
    • I
      inelsonSep 10, 2025
      If fluid is spitting from the gun, consider the following: * There might be air in the pump or hose: Check and tighten all fluid connections. Reprime the pump. * The tip might be partially clogged: Clear the tip. * The fluid supply might be low or empty: Refill the fluid supply. Prime the pump and check the fluid supply often to prevent running the pump dry.
  • S
    stonevictoriaSep 7, 2025
    Why Graco Construction Equipment engine won't start?
    • D
      Dr. Michelle PatelSep 8, 2025
      There are several reasons why your Graco Construction Equipment engine might not start: * The engine switch could be OFF: Turn the engine switch ON. * The engine could be out of gas: Refill the gas tank. * The engine oil level could be low: Replenish the oil. * The spark plug cable could be disconnected or damaged: Connect the spark plug cable or replace the spark plug. * The engine could be cold: Use the choke. * The fuel shutoff lever could be OFF: Move the lever to the ON position. * Oil could be seeping into the combustion chamber: Remove the spark plug, pull the starter 3 to 4 times, clean or replace the spark plug, and start the engine. Keep the sprayer upright to avoid oil seepage.
  • M
    Melissa EspinozaAug 22, 2025
    Why won't my Graco Paint Sprayer engine start?
    • A
      Austin PalmerAug 22, 2025
      If your Graco Paint Sprayer engine won’t start, there are several potential causes: * The engine switch may be OFF, in which case you should turn it ON. * The engine may be out of gas, so refill the gas tank. * The engine oil level may be low, so replenish the oil if necessary. * The spark plug cable may be disconnected or damaged, so connect or replace the spark plug. * If the engine is cold, use the choke. * The fuel shutoff lever may be OFF, so move it to the ON position. * Oil may be seeping into the combustion chamber; remove the spark plug, pull the starter 3 to 4 times, clean or replace the spark plug, and start the engine, keeping the sprayer upright to avoid oil seepage.
  • A
    Anthony MolinaSep 5, 2025
    Why is there high engine speed at no load in my Graco Paint Sprayer?
    • H
      Harold WilliamsSep 5, 2025
      If your Graco Paint Sprayer has high engine speed at no load, it may be due to: * A misadjusted throttle setting, so reset the throttle to 3700 -- 3800 engine rpm at no load. * A worn engine governor, so replace or service the engine governor.
  • R
    Raymond ArellanoSep 4, 2025
    Why is there low stall or run pressure shown on display of my Graco Paint Sprayer?
    • K
      Kathleen CarlsonSep 4, 2025
      If your Graco Paint Sprayer shows a low stall or run pressure on the display, it could be due to: * A new pump or new packings, as the pump break-in period can take up to 100 gallons of material. * A faulty transducer, so replace it.
  • R
    Robert LewisSep 2, 2025
    Why is there excessive hydraulic pump noise in my Graco Paint Sprayer?
    • R
      Ronald WoodSep 2, 2025
      If your Graco Paint Sprayer has excessive hydraulic pump noise, it is likely due to a low hydraulic fluid level. Shut off the sprayer and add fluid.
  • S
    Shawna LopezSep 1, 2025
    Why is the fluid delivery low on my Graco Paint Sprayer?
    • K
      Kathy LesterSep 1, 2025
      If the Graco Paint Sprayer fluid delivery is low, consider the following: * Increase the pressure setting. * Clean the displacement pump outlet filter if it's dirty or clogged. * Tighten the intake line to the pump inlet if it's not tight. * The hydraulic motor may be worn or damaged; bring the sprayer to a Graco distributor for repair. * If there's a large pressure drop in the fluid hose, use a larger diameter or shorter hose.
  • K
    Karla TownsendAug 31, 2025
    Why is my Graco Paint Sprayer overheating?
    • R
      Richard NealAug 31, 2025
      If the Graco Paint Sprayer is overheating, it could be due to: * Paint buildup on the hydraulic components, so clean them. * Low oil level, so fill it with oil.
  • L
    Latasha ArnoldAug 30, 2025
    What to do if Graco Paint Sprayer displacement pump operates, but output is low on up-stroke?
    • D
      djamesAug 30, 2025
      If your Graco Paint Sprayer's displacement pump operates, but the output is low on the up-stroke, it could be due to: * The piston ball not seating properly, so service the piston ball. * Worn or damaged piston packings, so replace the packings.
  • K
    kimberlyrushAug 28, 2025
    What to do if Graco Paint Sprayer engine operates, but displacement pump does not operate?
    • A
      Andrew AndersonAug 28, 2025
      If your Graco Paint Sprayer engine operates, but the displacement pump does not, check the following: * Ensure the pump valve is ON. * Increase the pressure setting by turning the pressure adjusting knob clockwise. * Clean the fluid filter. * Clean the tip or tip filter if clogged. * If the displacement pump piston rod is stuck due to dried paint, repair the pump. * Replace the belt if it's worn, broken, or off the pulley. * Add hydraulic fluid if it's too low. * If the hydraulic motor is not shifting, set the pump valve to OFF, turn the pressure down, turn the engine OFF, and pry the rod up or down until the hydraulic motor shifts.

Summary

Operation Overview

Important Safety Instructions

Highlights critical safety guidelines for operating the equipment.

General Safety Warnings

Fire and Explosion Hazard

Warns about risks of flammable fumes and static sparking during operation.

Skin Injection Hazard

Details dangers of high-pressure spray injecting into the body, requiring immediate treatment.

Equipment Safety Warnings

Carbon Monoxide Hazard

Alerts users to the danger of poisonous carbon monoxide gas from exhaust.

Equipment Misuse Hazard

Covers risks from fatigue, alcohol, exceeding pressure limits, and improper use.

Pressurized Aluminum Parts Hazard

Warns about chemical reactions with aluminum in pressurized systems causing rupture.

Moving Parts Hazard

Highlights risks of pinching, cutting, or amputating from moving components.

Entanglement Hazard

Describes dangers from rotating parts and loose clothing during operation.

Fluid and PPE Safety Warnings

Toxic Fluid or Fumes Hazard

Warns about serious injury or death from exposure to toxic fluids or fumes.

Burn Hazard

Advises caution regarding hot equipment surfaces and fluids to avoid severe burns.

Component Identification

Grounding Procedure

Pressure Relief Procedure

Setup and Startup

SwitchTip and Guard Assembly

Gun Placement

Straight Line Adjustment

Cleanup

Maintenance

Troubleshooting

Engine and Pump Operation Issues

Addresses common problems like engine starting failures, pump not operating, or low output.

Priming and Fluid Delivery Issues

Covers difficulties with priming, fluid spitting, leakage, overheating, and noise.

Hydraulic Oil;Filter Change

Graco LineLazer 130HS Specifications

General IconGeneral
BrandGraco
ModelLineLazer 130HS
CategoryConstruction Equipment