Cleanup
24 3A9031A
Cleanup
1. When using flammable material, follow
Grounding Instructions, page 9.
2. Follow Cleaning and Flushing Fluid
Compatibility, page 28.
3. Remove battery, see Battery
Installation and Removal, page 14.
4. Perform Pressure Relief Procedure,
page 10.
5. Remove Rac Guard and Rac Tip. For
additional information, see separate gun
manual.
6. Unscrew cap, remove filter. Assemble
without filter. Clean filter.
7. Clean gun filter (if installed), Rac Guard
and Rac Tip in flushing fluid. See
Cleanup, page 24.
8. Remove siphon tube set from paint and
place in flushing fluid. Use water or
pump conditioner for water-based paint
and mineral spirits for oil-based paint.
To avoid serious injury from fire and
explosion when using flammable materials:
• Do not spray solvents through the spray
tip. Always remove tip guard and spray
tip before flushing. Clean tip guard and
spray tip in a bucket of compatible
solvent.
• Clean in a well-ventilated area. Keep a
good supply of fresh air moving through
the area.
• When flushing with solvents, always
ground the striper and waste container.