Startup of Heated Units
24 311075R
Heating Foam Resins with
245 fa Blowing Agents
New foam blowing agents will froth at tempera-
tures above 90°F (33°C) when not under pres-
sure, especially if agitated.
Never fill the 7 gal. (26 l) supply tanks beyond
the 5 gal. (19 l) line on the tanks, to leave room
for some frothing.
At High Ambient Temperature (above
75°F/24°C)
Pour resins slowly to avoid frothing.
Only use Slow Recirc , to avoid heating
and agitating the tank. If temperature
doesn’t keep up, set function knob to
Stop/Park , then set to Slow Recirc
again.
When you stop to refill the tanks, avoid boil-
ing off fluid in the heaters by following these
steps:
a. Shut off Heater Power.
b. Leave hoses under pressure.
c. Fill tanks, page 19.
d. Set Recirc/Spray valves to Recirc.
e. Set function knob to Slow Recirc .
f. Turn on Heater Power.
At Cool Ambient Temperature (below
75°F/24°C)
Use Fast Recirc to heat tanks to
75-90°F. (24-32°C), then use Slow Recirc
to raise hose and gun to desired spray
temperature.
If the top of the resin in tank starts frothing,
do not use Fast Recirc any more.

Other manuals for Graco Reactor E-10