Pressure Relief Procedure
311075R 27
Pressure Relief
Procedure
Shutdown
1. Engage piston safety lock or trigger
safety lock.
2. Set function knob to Stop/Park .
3. Turn Recirc/Spray valves to Recirc.
Fluid will be dumped to supply tanks.
Pumps will move to the bottom of their
stroke. Ensure gauges drop to 0.
TI7069a
Fusion
2K Ultra-Lite
For longer breaks (more than 10 minutes),
use the following procedure. If you will be
shut down for more than 3 days, first see
Flushing, page 29.
1. Follow all steps of Pressure Relief Pro-
cedure, at left.
2. If using an impingement mix gun, close
gun fluid valves A and B. Doing this will
keep the internal parts of the gun
cleaner and prevent crossover.
3. Shut off Heater Power (heated units
only).
4. Shut off Motor Power.
5. Refer to your separate gun manual and
perform the Shutdown procedure.