Startup of Heated Units
22 311075R
Startup of Heated Units
Some models heat the fluid, which can cause
equipment surfaces to become very hot. To
avoid severe burns:
Do not operate Reactor E-10 without all
covers and shrouds in place.
Do not touch hot fluid or equipment.
Allow equipment to cool completely
before touching it.
Wear gloves if fluid temperature exceeds
110°F (43°C).
1. Perform Setup, pages 15-21.
2. Set function knob to Slow Recirc or
Fast Recirc . See Heatup Guide-
lines, page 23, then continue with steps
3-6.
OR
3. Turn on Heater Power.
4. Temporarily set heater control knobs to
maximum setting.
5. Circulate through heaters until tempera-
ture readouts display desired tempera-
ture. See TABLE 4 below.
6. Adjust heater control knobs as neces-
sary for a stable spray temperature.
Table 4: Heatup Time Guidelines for starting a cold machine with 5 gal. (19 l) per side (see
Notes below)
Fluid Spray Target
Temperature
35 ft (10.7 m) Hose
(1 bundle)
70 ft (21 m) Hose
(2 bundles)
125°F (52°C) 20 minutes 25 minutes
150°F (65°C) 40 minutes 50 minutes
Use fast circulation until temperature is within 20°F (11°C) of target,
then use slow circulation to reach final temperature.
Different fluids will absorb heat at different rates. When refilling a warm
machine, heatup times will be less.

Other manuals for Graco Reactor E-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor E-10 and is the answer not in the manual?

Graco Reactor E-10 Specifications

General IconGeneral
BrandGraco
ModelReactor E-10
CategoryPaint Sprayer
LanguageEnglish

Related product manuals