Cleanup and Storage
3A7649A 23
Static Grounding
Instructions
For disinfectants with alcohol active
ingredients or other flammable
disinfectants:
Always use a metal bucket for
disinfectants with alcohol active
ingredients, or other flammable
disinfectants, when sprayer is flushed or
cleaned.
Follow local code. Use only conductive
metal buckets, placed on a grounded
surface such as concrete.
Do not place bucket on a non-conductive
surface such as paper or cardboard
which interrupts ground continuity.
The waste bucket must be grounded to
reduce the risk of static sparking. A static
spark can cause fumes to ignite or
explode. A good ground provides an
escape wire for the electric current.