Startup
309665L 9
Startup
9 Turn prime valve down. 10 Place siphon tube set in grounded metal pail partially filled with flushing fluid. Attach ground
wire to pail and to true earth ground. Do 1. - 5. of Startup, page 9 to flush out storage oil
shipped in sprayer. Use water to flush water-base paint and mineral spirits to flush oil-base
paint and storage oil.
ti2719a
WASTE
FLUSH
ti2756B
1 Turn pressure control to
lowest pressure.
2 Turn power ON. 3 Increase pressure to start
motor and allow fluid
to circulate through drain
tube for 15 seconds; then
turn pressure down.
4 Turn prime valve
horizontal.Take spray gun
trigger safety OFF.
TIB
-
ti2706a
TIB
-
ti2712a