3A9322B 13
10. Reinstall the potentiometer, static wick,
trigger, and trigger lock components as
follows:
a. Ensure adjustment knob (33e) is
attached to the potentiometer.
NOTE: Alignment of #1 with the middle wire
is critical. See image below.
b. Place needle valve assembly (32)
into the smaller gun housing half.
Ensure all wires are underneath the
fluid tube, and the assembly is fully
seated into the gun housing.
NOTE: The potentiometer wires should
double back underneath the fluid tube as
shown.
c. Gently push the static wick wire
(black) into the wire channels with
a pencil eraser, then push the
static wick into the small cutout in
the back of the gun housing.
d. Use a pencil eraser to push the
white wires into the wire channels
(on top of the black wire). Place
adjustment knob assembly on the
three grooves at the bottom of the
gun housing.