310743A 29
2. Start and prime the pump.
3. Disengage the trigger lock and trigger the gun into a
metal waste container.
4. Release the trigger; the gun should immediately stop spraying and there should not be any leaks. If there is a
problem, follow the Pressure Relief Procedure on page 10. Check through Assembly procedure and correct
problem.
5. Install tip and tip guard before regular use.
T5047A
TI5048A