Flushing
310665E 17
4. Disengage trigger lock and trigger gun into a
grounded pail. Flush out about 1 pint (500 cc) of
mixed material. Engage trigger lock.
5. Close solvent purge valve J
A
.
6. Open solvent purge valve J
B
. Flush out about 1 pint
(500 cc) of mixed material. Engage trigger lock.
TI5047a TI5049aTI5048a
AB
J
B
J
A
7. Re-open solvent purge valve J
A
.
8. Disengage trigger lock, and flush through gun until
clean solvent flows. Engage trigger lock.
9. Close solvent purge valves J
A
and J
B
.
10.Trigger gun to relieve solvent pressure. Engage trig-
ger lock.
AB
J
B
J
A
TI5047a TI5049aTI5048a