Priming
22 310665E
Priming
Do not install the gun spray tip yet. Use the lowest
possible pressure while priming, to avoid splash-
ing.
1. Fill A (blue) and B (green) fluid reservoirs with
proper materials.
2. Turn both 3-way ball valves to open reservoir lines,
as shown below. Arrow on handle shows direction of
flow.
3. Set air regulator to 0.
A
B
4. Close fluid shutoff valves G
A
and G
B
.
5. Place a container under each sampling valve. Open
sampling valve H
A
slowly.
6. Turn function knob to A . Press . Turn up
air regulator slowly until pump A starts.
G
A
G
B
H
A
When run independently (set to A or B), the pump
runs for 12 cycles, then stops. Press and
as needed to prime. Monitor containers to avoid
overflowing.