Shutdown
310665E 31
Shutdown
Follow this procedure before prolonged shutdown or
servicing equipment.
2. Follow Flushing, page 16.
3. Follow Pressure Relief Procedure, pages 14 and
15. Engage trigger lock.
4. Before prolonged shutdown: cap fluid outlets to
keep solvent in the lines. Fill pump A and B packing
nuts and dispense valve A and B wet cups with
throat seal liquid (TSL).
1. Follow Pressure Relief Procedure, page 14.
Engage trigger lock, set air regulator to 0, and close
main air shutoff valve. Remove spray tip.