Wash water does not maintain 1.That automatic breaker F1 in the distribution box is in
position 1.
the right temperature 2.That the thermistor is undamaged and the temperature is
correctly set.
Final rinse water does not maintain 1.That automatic breaker F1 in the distribution box is in
position 1.
right temperature 2.That the thermistor is undamaged and the temperature is
correctly set.
3.That inlet water is approx. 55 °C.
The meaning of the error codes can be read out from the table below.
Error code 100, 109, 116, 118, 132 are also displayed with an Error message text shown in the
Meaning column.
When an error code is displayed, the program always is cancelled.
After checking or taken care of the problem, the alarm can be reset by pressing the STOP-
button.
Error
code Machine Meaning Cause Remedy
001
All
Programme cancelled by
operator.
This error code is displayed only when
operating data is read in GDTdirect™
3.x.
100
Flexi
Maxi
Spray pipe alarm
Something is preventing
movement of the spray
pipes.
Remove whatever is preventing
movement. Check the magnetic
proximity switch and the magnet on the
rocking arm. Check the fuse F4 on the
PCB
101 Maxi
Combi
Motor circuit breaker for
wash pump right tripped
The motor is overloaded
The impeller is blocked
by granules or by small
utensil
Check if the impeller turns free, reset
the motor circuit breaker, start the
machine and check the current of all
three phases Check the volume of
charged granules.
102 Maxi
Combi
Motor circuit breaker for
wash pump left tripped
The motor is overloaded
The impeller is blocked
by granules or by small
utensil
Check if the impeller turns free, reset
the motor circuit breaker, start the
machine and check the current of all
three phases. Check the volume of
charged granules.
103
All Motor circuit breaker for
rinse pump tripped out.
The motor is overloaded
The impeller is blocked
Check if the impeller turns free, reset
the motor circuit breaker, start the
machine and check the current of all
three phases