LDX 86 HS/XS HiSpeed/XtremeSpeed HD camera User’s Guide (v1.0) 73
Chapter 5 - Video setup
6. A message indicating that the process is running appears:
If there is insufficient light, the “light level too low” message appears in the viewfinder.
7. When the process is completed (within a few seconds) the OK message and the
measured color temperature appears in the viewfinder. On the OCP 400 the button light is
switched off.
The measured color temperature is now stored in the selected memory position and can be
recalled as required.
If the auto-white measurement has been unsuccessful, the light in the WHITE BALANCE
button on the OCP 400 is orange.
During the auto-white measurement process the iris is set to Auto and 90% and knee is
switched off.
Black balance is not necessary because black level is automatically adjusted by the camera’s
internal video circuits.
5.8.7 Saturation
Adjust the saturation level to increase or decrease color of the picture. Saturation values below
100% decrease colors while values higher than 100% increase colors.
Press the COLOR button, select the SATURATION item and adjust the level.
In the camera menu, navigate to the PRODUCTION SETUP > COLOR > SATURATION item and
adjust the level
AWHITE: running
OCP
CAM