Unit MAINTENANCE
47
1.TROUBLESHOOTING
Panel TB03 displaying the error code :
Error code
Error
E0
Water pump error
E6
Communications error
F0
temperature sensor error at the return air inlet
F1
Evaporator temp. sensor error
F5
temperature sensor error at the wire controller
E9
Full water protection
FE
Entering cooling temp. sensor error of the evaporator
2.CARE AND MAINTENANCE
Please pull out the power plug after you used the air condition.
Warning:
(1) Pull out the power plug before cleaning.
(2) Do not splash water directly.
How to clean the air filter
Open the suction grille.
Slide both knobs simultaneously as shown and then pull them downward
slowly.
Remove the air filters.
Slide knobs on the back of the suction grille out ward and remove the air
filter.
Then remove three air cleaners on it.
Clean the filter
Use vacuum or wash the air filter with water when the air filter is very dirty,
use neutral detergent and water. Let the filter dry naturally at shady place.
Note:
a. Do not clean with hot water.

Other manuals for Gree FP-85XD/B-T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree FP-85XD/B-T and is the answer not in the manual?

Gree FP-85XD/B-T Specifications

General IconGeneral
BrandGree
ModelFP-85XD/B-T
CategoryAir Conditioner
LanguageEnglish

Related product manuals