EasyManua.ls Logo

Gree U-MATCH GUHD09NK3CO - Page 179

Gree U-MATCH GUHD09NK3CO
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A/A DC INVERTER U-MATCH AIR CONDITIONERS MAINTENANCE
176
7. Assemble the electric box
cove
Assemble the electric box
cover to correct position and
use screwdriver to tighten the
fixing screws.
Double-fan Inverter Outdoor Unit, applicable to GUHD36NK3CO/GUHD36NM3CO
/GUHD42NK3CO/ GUHD42NM3CO/
Disassembly and Assembly of external casing
Remark : Before removing the outer housing, make sure that the unit has been cut off from the
power supply.
Step Illustration Handling Instruction
1 Disassemble the top panel
a. Cut off the power supply
b. Recover the refrigerant
c. Loosen the screws on the top
panel with a screw driver.

Table of Contents

Related product manuals