A/A DC INVERTER U-MATCH AIR CONDITIONERS MAINTENANCE
209
3Pull out the water
outlet pipe and
loosen the screws
fixing the water
pump.
Pull out the water outlet pipe and
use screwdriver to loosen the
screws fixing the water pump.
emoval and Installation of Drainage Pump
Step Illustration Handling Instruction
4 Take out the pump and
replace it
Take out the pump and replace
it
5Connect the drainage pipe
and tighten the screws
fixing the water pump.
Connect the drainage pipe and
use screwdriver to tighten the
screws fixing the water pump.
6Mount the water tray and
tighten the screws
Use screwdriver to loosen the
screws fixing the water tray
1 Loosen these screws
2. Loosen the screws fixing the water pump
1 Loosen these screws
2. Loosen the screws fixing the water pump
Loosen these screws