A/A DC INVERTER U-MATCH AIR CONDITIONERS INSTALLATION
76
noise and oscillate.
The horizontally of the installation place should be guaranteed.
Select the place where is easy to drain out the condensate water, and connect with outdoor unit.
Make sure that there are enough space for care and maintenance. Make sure that the weight between the
indoor unit and ground is above 2300mm.
When installing the steeve bolt, check if the install place can stand the weight 4 times of the
unit’s. If not, reinforce before installation. (Refer to the install cardboard and find where should be reinforced)
The appliance shall not be installed in laundry.
Cautions:
There will be lots of lampblack and dust stick on the acentric, heat exchanger and water pump in dining room
and kitchen, which would reduce the capacity of heat exchanger, lead water leakage and abnormal operation of the
water pump.
The following treatment should be taken under this circumstance:
Ensure that the smoke trap above cooker has enough capacity to obviate lampblack to prevent the indraft of
the lampblack by the air conditioner.
Keep the air conditioner far from the kitchen so that the lampblack would not be indraft by the air conditioner.
1.3.3 Caution for Installation
1) Important notice:
To guarantee the good performance, the unit must be installed by professional personnel according with this
instruction.
Please contact the local Gree special nominated repair department before installation. Any malfunction caused
by the unit that is installed by the department that is not special nominated by Gree would not deal with on time
by the inconvenience of the business contact.