INSTALLATION SUPPLEMENTS
Refer to the appropriate Greenheck installation
supplements for special requirements:
Shaftwall Supplement
Drywall Supplement
Wood Supplement
Smoke Detector Supplement
Tunnel Corridor Supplement
Single Side Retaining Angle Supplement
Grille Installation Supplement
Field Installed Sleeve Supplement
Installation,Operation and
Maintenance Instructions
for FSD-XXX, DFD-XXX,DFDTF-XXX
CFSD-XXX,SEDFD-XXX, SEFSD-XXX,
IMO-XXX, AND SSFSD-XXX SERIES
1
1
2 and 3 Hour
Fire & Combination Fire Smoke Dampers
(with factory installed sleeve and actuator)
Vertical and Horizontal Mount
Part #461336
SAFETY WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause property damage,
injury or death. Read the installation, operating,
and maintenance instructions thoroughly before
installing or servicing this equipment.
This manual is the property of the owner, and is required
for future maintenance. Please leave it with the owner
when the job is complete.
Typical Actuator
RRL Control Device
Standard
WARRANTY
Greenheck warrants this equipment to be free from
defects in material and workmanship for a period of one
year from the purchase date. Any units or parts which
prove to be defective during the warranty period will
be repaired or replaced at our option. Greenheck shall
not be liable for damages resulting from misapplication
or misuse of its products. Greenheck will not be
responsible for any installation or removal costs.
Greenheck will not be responsible for any service work
or backcharges without prior written authorization.
Due to continuing research, Greenheck reserves the right to change specifications without notice.
“UL CLASSIFIED (see complete marking on product)”
“UL CLASSIFIED to Canadian safety standards (see
complete marking on product)”
UL Standard 555 & 555S (Classification #R13317)
FSD-XXX, SEFSD-XXX, SSFSD-XXX, DFD-XXX, SEDFD-XXX,
and CFSD-XXX Series Dampers are intended for installation
in accordance with combination fire smoke damper
requirements established by:
National Fire Protection Association
NFPA Standards 90A, 92A, 92B & 101
BOCA National Building Codes
ICBO Uniform Building Codes
IBC International Building Codes
SBCCI Standard Building Codes
New York City
(MEA listing #260-91-M)
California State Fire Marshal
(Listing #3225-0981:103)
and (Listing #3230-0981:104) - FSD models; (Listing #3225-
0981:103) - DFD models; (Listing #3230-0981:105) and (Listing
3225-0981:106) - CFSD models; (Listing #3225-0981:109) and
(Listing 3230-0981:110 ) - SSFSD models
RECEIVING AND HANDLING
Upon receiving dampers, check for both obvious and
hidden damage. If damage is found, record all necessary
information on the bill of lading and file a claim with
the final carrier. Check to be sure that all parts of the
shipment, including accessories, are accounted for.
Dampers must be kept dry and clean. Indoor storage
and protection from dirt, dust and the weather is highly
recommended. Do not store at temperatures in excess of
100°F.

Other manuals for Greenheck DFD-210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Greenheck DFD-210 and is the answer not in the manual?

Greenheck DFD-210 Specifications

General IconGeneral
BrandGreenheck
ModelDFD-210
CategoryFire and Smoke Dampers
LanguageEnglish

Related product manuals