Greenline 33 55
BATTERY MONITORING - BMV
The battery monitor shows important data about the main 48V LiPo battery bank and about the 12V service
battery.
Standard information and alarms:
- Battery voltage of LiPo battery (full battery @ 54.3V).
- Battery voltage of service battery (full battery @ 14.4V).
- Battery charge/discharge current (A): - consumption, + charging
- Ampere-hours consumed (Ah).
- Battery status (%).
- Time to go (time to empty) at the current rate of discharge (see Victron owner`s manual).
- Visual and audible alarm: over and under voltage. (During an alarm the buzzer will sound. The alarm buzzer
can be silenced by pressing any button.)
For switching between the data screens press »+« or »-«. For detailed information and changing the settings,
please read the manufacturer's owner's manual.
If the battery voltage drops under 44V, the alarm will turn ON (it will
turn OFF after voltage rises above 46V) – turn off all consumers (incl.
propulsion) and recharge the battery.
If the battery voltage rises above 54.7V, the alarm will turn ON (it will
turn OFF after voltage drops under 54.4V) – turn off the power sources
(generator, shore cable) and discharge the battery (with propulsion or