Picture 22: Kitchen 230V sockets
Picture 23: Salon 230V sockets above port locker
Picture 24: Cabin 230V sockets under the port bed
Picture 25: Toilet 230V socket
Other 230V consumers are preplugged. These are (full option): 12V battery charger, air conditioning, water
heater, 2x LCD TV, 2x DVD player, fridge, electric hob, microwave oven.
When using 230V power you have to turn ON fuses F38-F42 (see table
2). Fuse F41 (water heater) is also a switch! Turn F41 OFF if you are not
using water heater.
Maximal power consumption under 230V wiring system is 3kW. If you
overload the system the circuit breaker will go trip.
Maximal power consumption under 230V wiring system through
inverter is 3kVA (2.5kW). If you overload the system the red light
»overload« on phoenix multi control (on console) will illuminate and the
power will go out. Reduce the consumption!