- Turn OFF all main switches (S1-S6)
- Disconnect shore power (see shore power chapter)
- Turn OFF fuse F38 and F39.
- Leave F17-F23 always ON (also written on DC panel)
- It is highly recommended to turn OFF F11 (cockpit lights)
Winter storage:
For winter storage it is recommended to turn OFF all the consumers
from boat batteries.
- Turn OFF all main switches (S1-S6)
- Disconnect shore power (see shore power chapter)
- Turn OFF fuse F38 and F39.
- Turn OFF F11 (cockpit lights)
- You can also turn OFF diesel heater (F20, make sure that it is cooled
before turning OFF)
- In water leave F17 ON (bilge pump)
- Out of water turn OFF F17 (bilge pump)
Winter storage LiPo battery bank:
To prevent LiPo battery from damaging you have to store it in
temperature range from -20°C to +60°C at SOC 40% - 60% (app. 48V). In
case when the boat can not be stored in this temperature range, you
have to un-mount the LiPo battery and store it somewhere else to meet
the temperature range.