2.9.3
Step 2
Press Bathroom or Kitchen button
- light will go solid
Boost Airflow button will flash
– factory setting:
Press speed adjustment buttons to
required level and verify
- re-press Boost button to confirm
Trickle Airflow button will flash
– factory setting:
Press speed adjustment buttons to
required level and verify
- re-press Trickle button to confirm
Step 1
Step 3
For HumidiSMART press button to
turn on
- light will go solid
For TimerSMART press button to
turn on
- light will go solid
Step 5
Step 4
Bathroom 8 l/s Kitchen 13 l/s
Bathroom 5 l/s Kitchen 8 l/s
Note: Selection lights should remain on for approximately 10 seconds to
enable the setup and status of the fan to be observed and checked, upon
which time the selected commissioning settings should lock out.
Commissioning
On first power up, both
Bathroom and Kitchen Room
selection button lights should
start to flash to indicate that
an appropriate installation
setting needs to be selected.