4 OM-GSSP-BL-E BOILERLESS STEAMER
USER SETTINGS
SYMBOL GUIDE
Temperature Ready This symbol is green and is found in the upper left
corner of your screen. It is visible when the unit has reached temperature.
Door Open This symbol is orange and is found in the upper left corner of
your screen. It is displayed when the door is open.
Menu This menu option is found in the upper right corner of your display
and is accessible from most screens. This is how you access all settings
and user information.
Back Button This button is displayed in the upper right corner of your
screen and is used to return to a previous screen or menu.
Scroll Button These buttons are displayed when options can not t on
your screen. Press appropriate button to scroll up or scroll down to access
further options.
Exit Button Any image with an X communicates an exit option.
+1m Button This button is found on steamer timer pages and allows you
to quickly add 1 minutes to the steam time.
MENU OPTIONS
The items shown on the right of all the menu screens (shown with blue text) can
be changed by tapping the blue text. It will cycle through the options. Only items
with blue text or a slider button can be changed.
Settings
INITIAL START-UP
WARNING: WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF
THE UNIT. STEAM CAN CAUSE BURNS.
START-UP
After the Boilerless Steamer has been installed, test it to ensure that the unit is
operating correctly.
1. Remove all literature and packing materials from the interior and exterior of
the unit.
2. Make sure the water supply line is open.
3. Turn on electrical service to the unit. The steamer will not operate without
electrical power. Do not attempt to operate the unit during a power failure.
NOTE: The door MUST be closed in order for unit to heat.
4. There is an on/off switch in the rear of the unit. Conrm that is it in the ON
position.
5. To turn the unit on, press the power button on the front control panel. The
power button will light up and the touch screen will display that the unit is
going through self diagnostics.
NOTE: DELIME button is only displayed
during startup if the DELIME button is
turned to ON in settings menu. The
default setting for DELIME button is OFF.
Performing self-diagnostic
Performing self-diagnostic
6. Upon completion of self diagnostics, the screen will transition to the manual
cook screen and the unit will begin pre-heating. If exited, the screen will
transition to the home screen where it will continue to pre-heat.
Heating
In Progress
SHUTDOWN H:MM:SS
7. On initial start up, the installer needs to record the startup date in the controls.
Go into the MENUàSERVICEàSTARTUP DATE, and enter the date. After this
date is set, it cannot be changed. To exit this menu, hit the back arrow until you
return to the home screen.
SHUT-DOWN
1. To shut down the unit, press the power button on the front control panel. The
steam generating reservoir will then ll with cold water and drain. You will see
a shutdown progress bar on the display.
Shutdown in process,