EasyManua.ls Logo

Grow GM65 - Command Triggered Mode

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Sleep mode on Sleep mode off
Default: come into sleep mode after 30s free. Wake up by key. Module will restart after dropping out
sleep mode.
3.4 Command Triggered Mode
Module begins to read when receive scan command from mainframe( bit0 of zone bit 0x0002
writes”1”) , and stop at output or read timeout.
Command triggered mode
Under command triggered mode, command for serial port trigger is 7E 00 08 01 00 02 01 AB CD;
After receiving command, model will output 02 00 00 01 00 33 31” and start scan.
Time settlement for single read
Read and Scan time before output. From 0.1s to 25.5s, step size 0.1s. 0 : infinite time interval;
Default: 5s
1000ms 3000ms
Default 5000ms infinite time interval