EasyManua.ls Logo

Growatt MAX 175KTL3-X HV - User Manual

Growatt MAX 175KTL3-X HV
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GR-UM-255-A-00
Shenzhen Growatt New Energy Co., Ltd
4-13/F,Building A,Sino-German(Europe) Industrial Park,
Hangcheng Ave, Bao'an District, Shenzhen, China
T: +86 755 2747 1942
E :service@ginverter.com
W :www.ginverter.com
Installation
&
Operation Manual
Download
Manual
Growatt New Energy

Questions and Answers

  • G
    gjonesSep 16, 2025
    What to do if Growatt MAX 175KTL3-X HV Inverter showing Error 402?
    • J
      John StewartSep 16, 2025
      If your Growatt Inverter displays Error 402, restart the inverter. If the problem continues, contact Growatt.
  • S
    Sara BrewerAug 25, 2025
    How to fix Warning 400 on a Growatt Inverter?
    • E
      Eric PierceAug 25, 2025
      If you see Warning 400 on your Growatt Inverter, shut it down first. Then, check the fan connection. If the issue continues, replace the fan. If the problem still persists, contact Growatt.
  • K
    Kimberly DiazAug 25, 2025
    How do I troubleshoot Error 304 on my Growatt MAX 175KTL3-X HV?
    • K
      kristopher89Aug 26, 2025
      If your Growatt Inverter displays Error 304, verify that the frequency is within the specified range. If it is not, or the error persists, contact Growatt.
  • M
    Michael RuizAug 26, 2025
    How to solve Error 302 on a Growatt Inverter?
    • T
      Timothy MorganAug 27, 2025
      If your Growatt Inverter shows Error 302, shut down the system and check the AC wiring. If the issue persists, contact Growatt.
  • B
    Bonnie SchroederSep 18, 2025
    What to do if Growatt MAX 175KTL3-X HV Inverter showing Error 403?
    • J
      justin98Sep 18, 2025
      If your Growatt Inverter displays Error 403, restart the inverter. If the problem continues, contact Growatt.
  • S
    Steve BakerSep 23, 2025
    What to do if Growatt Inverter showing Error 407?
    • B
      berryjenniferSep 23, 2025
      If your Growatt Inverter displays Error 407, restart the inverter. If the problem continues, contact Growatt.
  • K
    kimberlyperrySep 8, 2025
    What to do if Growatt MAX 175KTL3-X HV Inverter showing Error 421?
    • C
      Catherine VasquezSep 8, 2025
      If your Growatt Inverter displays Error 421, restart the inverter. If the problem continues, contact Growatt.
  • D
    Deborah JohnsonSep 9, 2025
    What to do if Growatt Inverter showing Error 422?
    • S
      Scott KramerSep 9, 2025
      If your Growatt Inverter displays Error 422, restart the inverter. If the problem continues, contact Growatt.
  • M
    michael40Sep 3, 2025
    What to do if Growatt Inverter showing Warning 407?
    • L
      Lauren MitchellSep 3, 2025
      If your Growatt Inverter displays Warning 407, restart the inverter. If the problem continues, contact Growatt.
  • S
    Steven GarciaSep 1, 2025
    What to do if Growatt MAX 175KTL3-X HV showing Warning 405?
    • C
      Christine HillSep 1, 2025
      If your Growatt Inverter displays Warning 405, restart the inverter. If the problem continues, contact Growatt.

Growatt MAX 175KTL3-X HV Specifications

General IconGeneral
ModelMAX 175KTL3-X HV
Max DC Input Current per MPPT30 A
DC Inputs per MPPT2
AC Grid Frequency50/60 Hz
THDi< 3 %
European Efficiency98.5%
DC SwitchYes
Protection DegreeIP66
Altitude4000 m
Rated Power175000W
Rated AC Output Power175 kW
AC Nominal Voltage400 V
Power Factor0.8 leading to 0.8 lagging
Humidity0-100 %
CommunicationRS485
CertificationsRD 1699

Related product manuals