Off Grid Solar Inverter
Split Phase 18KW
Version: 1.0
User Manual

Questions and Answers

  • A
    Amber HansenAug 20, 2025
    How to fix Growatt SPF 18KT DVM-MPV Inverter that shuts down automatically during startup?
    • D
      Dawn MosesAug 21, 2025
      If your Growatt Inverter shuts down automatically during startup, it could be due to a low battery voltage (less than 1.91V/Cell). Try re-charging the battery. If the problem persists, consider replacing the battery.
  • H
    Heather DavisSep 1, 2025
    What to do if my Growatt Inverter has no response after power on?
    • L
      Linda JohnsonSep 1, 2025
      If your Growatt Inverter is not responding after you power it on, it could be due to several reasons: * The battery voltage might be too low (less than 1.4V/Cell). Check the battery and wiring connections. * The battery polarity might be reversed. Re-charge the battery. * The battery might need replacement.
  • J
    joshuahensonNov 11, 2025
    Why does my Growatt SPF 18KT DVM-MPV beep continuously and the red LED is on?
    • J
      Jacob BernardNov 11, 2025
      If the Growatt Inverter's buzzer beeps continuously and the red LED is on, several issues could be the cause. It might be due to an MPPT or Inverter Fan abnormality, requiring a fan replacement. The internal component temperature may be too high (over 90°C), suggesting a need to check for airflow blockages or high ambient temperatures. Other potential causes include an over-charged or excessively high battery voltage, a short-circuited output, or an abnormal output voltage (below 180Vac or above 290Vac), each necessitating specific checks and corrections. Also, overload error can cause this problem, so reduce the connected load by switching off some equipment. Other reasons include solar controller over temperature (check air flow), no battery connected (check battery cable), BMS communica...

Growatt SPF 18KT DVM-MPV Specifications

General IconGeneral
ModelSPF 18KT DVM-MPV
CategoryInverter
Rated Power18000 W
Max. PV Input Power22000 W
Number of MPPTs2
Efficiency97.6%
Weight48 kg
Nominal Output Power18000VA / 18000W
AC Output Voltage230VAC
AC Output Frequency50/60Hz
Battery Voltage48 V
Battery Voltage Range40 V - 60 V
Operating Temperature Range-25°C to +60°C
Cooling MethodSmart Cooling
CommunicationRS485, WiFi, GPRS
Protection Featuresover temperature, over load, short circuit, over voltage