Model
Specifications
Growatt
SPH3000
Growatt
SPH3600
Growatt
SPH4000
Growatt
SPH4600
Growatt
SPH5000
Growatt
SPH6000
AC connection
Stand alone(AC
power)
Rated AC output
power
Rated AC output
voltage
Rated AC output
frequency
Starting mode
BAT data(DC)
Single
phase
Single
phase
Single
phase
Single
phase
Single
phase
Single
phase
3000W3000W3000W3000W3000W3000W
230Vac
50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz
230Vac 230Vac 230Vac 230Vac 230Vac
Setup Setup Setup Setup Setup Setup
42~59V 42~59V 42~59V 42~59V42~59V 42~59V
66A 66A 66A 66A 66A 66A
3000W 3000W 3000W 3000W 3000W 3000W
lithium /
Lead-acid
lithium /
Lead-acid
lithium /
Lead-acid
lithium /
Lead-acid
lithium /
Lead-acid
lithium /
Lead-acid
80% /50% 80% /50% 80% /50% 80% /50% 80% /50% 80% /50%
3~12kWh 3~12kWh 3~12kWh 3~12kWh 3~12kWh 3~12kWh
97.1%
96.8%
99.5% 99.5% 99.5% 99.5% 99.5% 99.5%
97.2%
96.9%
97.2%
96.9%
97.3%
97%
97.3%
97%
97.5%
97.1%
yes yes yes yes yes
yes
Battery voltage
range
Max charging
voltage
Max charging and
discharging
current
Type of battery
DoD
Capacity of
battery
Efficiency
Max. efficiency
Euro weighted
efficiency
CEC efficiency
MPPT efficiency
Protection
devices
DC reverse polarity
protection
Max charging and
discharging
power
<3% <3% <3% <3% <3% <3%
THDI
58V 58V 58V 58V 58V 58V
56
55
Model
Specifications
Growatt
SPH3000
Growatt
SPH3600
Growatt
SPH4000
Growatt
SPH4600
Growatt
SPH5000
Growatt
SPH6000
Output over
current protection
Output over
voltage protection-
varistor
Ground fault
monitoring
Grid monitoring
Integrated all -
pole sensitive
leakage current
monitoring unit
General Data
Dimensions (W / H
/ D) in mm
Weight
Noise emission
(typical)
Altitude
Self-Consumption
Inverter Topology
DC/DC topology
Cooling concept
Environmental
Protection Rating
Relative humidity
DC connection
AC connection
Features
Operating
temperature
range
BAT reverse
protection
yes
yes
yes
yes
yes
yes
450*565
*180
27KG
25°C ...
+6Cwith
derating
above 45°C
25°C ...
+6Cwith
derating
above 45°C
25°C ...
+6Cwith
derating
above 45°C
25°C ...
+6Cwith
derating
above 45°C
25°C ...
+6Cwith
derating
above 45°C
25°C ...
+6Cwith
derating
above 45°C
25 dB(A)
2000m2000m2000m2000m2000m2000m
< 4 W
transfor
merless
HF
transformer
HF
transformer
Natural
IP65
100%
MC4/H4
(opt)
connector connector connector connector connector connector
MC4/H4
(opt)
MC4/H4
(opt)
MC4/H4
(opt)
MC4/H4
(opt)
MC4/H4
(opt)
100% 100% 100% 100% 100%
IP65 IP65 IP65 IP65 IP65
Natural Natural Natural Natural Natural
HF
transformer
HF
transformer
HF
transformer
HF
transformer
transfor
merless
transfor
merless
transfor
merless
transfor
merless
transfor
merless
< 4 W < 4 W < 4 W < 4 W < 4 W
25 dB(A)25 dB(A)25 dB(A)25 dB(A)25 dB(A)
27KG 27KG 27KG 27KG 27KG
450*565
*180
450*565
*180
450*565
*180
450*565
*180
450*565
*180
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes

Other manuals for Growatt SPH4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH4000 and is the answer not in the manual?

Growatt SPH4000 Specifications

General IconGeneral
ModelSPH4000
CategoryInverter
Rated Power4000 W
Max. DC Voltage550 V
MPPT Voltage Range120 V - 500 V
Number of MPPTs2
AC Output Voltage230 V
Frequency50/60Hz
Efficiency97.5%
Start Voltage150 V
Nominal DC Voltage360V
Max. Input Current per MPPT11 A
AC Nominal Power4000 W
Max. AC Apparent Power4000 VA
AC Voltage Range180 V - 280 V
Power Factor0.8 leading to 0.8 lagging
THDi<3%
AC Connection TypeSingle phase
Max. Charge/Discharge Power4000 W
Nominal Battery Voltage48 V
Communication with BMSCAN/RS485
Operating Temperature Range-25°C to +60°C
Protection DegreeIP65
TopologyTransformerless
Weight25 kg
Max. PV Input Voltage550 V
Cooling MethodNatural Convection

Related product manuals